| RS PRO | 9V c.c. | 500mA | 12 → 36V c.c. | Montage en surface | 1 | CMS | - | 93/90% | 50mV Pk-Pk | +85°C | -40°C | - | ±0.4% |
|
| TRACOPOWER | 5V c.c. | 2A | 6.5 → 36V c.c. | Montage sur CI | 1 | SIP 3 | - | 94% | 50mV Pk-Pk | +85°C | -40°C | TSR 2 | Maximum of 0.5% |
|
13,11 € l'unité (conditionné en tube) | TRACOPOWER | -5V c.c. | -1A | -7.5 → -32V c.c. | Montage traversant | 1 | - | - | 92% | 50mV Pk-Pk | +85°C | -40°C | TSN 1 | 1% |
|
| Recom | 5V c.c. | 1A | 8 → 28V c.c. | Montage traversant | 1 | SIP | 5W | 85% | 120mV Pk-Pk | +85°C | -40°C | R-78E-1.0 | ±1% |
|
| TRACOPOWER | 3.3V c.c. | 1A | 4.75 → 36V c.c. | Montage traversant | 1 | SIP 3 | 3.3W | - | 50mV Pk-Pk | +85°C | -40°C | TSR 1 | ±0.2% |
|
| TRACOPOWER | 9V c.c. | 2A | 12 → 36V c.c. | Montage traversant | 1 | SIP | - | 95% | 75mV Pk-Pk | +85°C | -40°C | TSR 2 | Maximum of 0.5% |
|
| TRACOPOWER | 12V c.c. | 2A | 15 → 36V c.c. | Montage traversant | 1 | SIP 3 | - | 95% | 75mV Pk-Pk | +85°C | -40°C | TSR 2 | Maximum of 0.5% |
|
| XP Power | 5V c.c. | 1A | 8 → 28V c.c. | Montage traversant | 1 | SIP | - | 90% | 100mV Pk-Pk | +85°C | -40°C | TR10 | 1% |
|
| TRACOPOWER | 9V c.c. | 1A | 12 → 36V c.c. | Montage traversant | 1 | SIP 3 | 9W | 95 → 89% | 75mV Pk-Pk | +85°C | -40°C | TSR 1 | ±0.2% |
|
| XP Power | 5V c.c. | 1A | 8 → 36V c.c. | - | 1 | - | - | - | - | - | - | - | - |
|
| TRACOPOWER | 5V c.c. | 1A | 6.5 → 36V c.c. | Montage traversant | 1 | SIP 3 | 5W | 93 → 84% | 50mV Pk-Pk | +85°C | -40°C | TSR 1 | ±0.2% |
|
| TRACOPOWER | 1.5V c.c. | 1A | 4.6 → 36V c.c. | Montage traversant | 1 | SIP 3 | 1.5W | 78 → 65% | 50mV Pk-Pk | +85°C | -40°C | TSR 1 | ±0.2% |
|
| TRACOPOWER | 6.5V c.c. | 600mA | 9 → 72V c.c. | Montage traversant | 1 | - | - | 91% | 50mV Pk-Pk | +80°C | -40°C | TSR 0.6-4865WI | ±2.5% |
|
| XP Power | 5V c.c. | 500mA | 6.5 → 36V c.c. | - | 1 | - | - | - | - | - | - | - | - |
|
| Recom | 5V c.c. | 500mA | 7 → 28V c.c. | Montage traversant | 1 | SIP | 2.5W | 92% | 50mV Pk-Pk | +85°C | -40°C | R-78E-0.5 | ±0.5% |
|
11,91 € l'unité (conditionné en tube) | TRACOPOWER | ±1.5V c.c. | 1 A, 600 mA | 4.6 → 32 V dc, 4.6 → 42 V dc | Montage traversant | 1 | SIP | - | 64%, 66% | 50mV Pk-Pk | +85°C | -40°C | - | ±0.2% |
|
| TRACOPOWER | 5 V dc, -5 V dcV c.c. | 1 A, 400 mA | 4.6 → 31 V dc, 6.5 → 42 V dc | Montage traversant | 1 | SIP | - | 78%, 83% | 75mV Pk-Pk | +85°C | -40°C | - | ±0.2% |
|
| TRACOPOWER | 6.5V c.c. | 2A | 9 → 36V c.c. | Montage sur CI | 1 | SIP 3 | - | 94% | 50mV Pk-Pk | +85°C | -40°C | TSR 2 | Maximum of 0.5% |
|
| TRACOPOWER | 15V c.c. | 2A | 18 → 36V c.c. | Montage traversant | 1 | SIP | - | 96% | 75mV Pk-Pk | +85°C | -40°C | TSR 2 | Maximum of 0.5% |
|
| Recom | 12V c.c. | 500mA | 15 → 32V c.c. | Montage traversant | 1 | SIP 3 | - | 97% | 35mV Pk-Pk | +85°C | -40°C | R-78W-0.5 | 0.2% |